Why does the centrifugal compressor experience rubbing vibration?
2026-06-11 19:24

Rub-impact vibration is one of the most common faults in centrifugal compressors. It is mainly triggered by friction between rotating and stationary components, which brings severe hazards. In serious cases, the compressor will fail to operate completely and its service life will be shortened.

Rub-impact vibration generates mechanical force shock and thermal shock, among which thermal shock causes more severe damage. It belongs to nonlinear vibration with unstable waveform and rotor orbit, and the fundamental frequency serves as the main component. Multiple factors affect rub-impact, including eccentricity, rotating speed, offset value, radial clearance and stator radial stiffness. Experiments verify that eccentricity exerts a prominent influence on rub-impact vibration characteristics. This paper summarizes identification methods for rub-impact positions and briefly introduces mainstream diagnostic techniques. The Hilbert-Huang Transform (HHT) clearly displays the frequency, time and amplitude of rub-impact vibration, enabling early, rapid and accurate fault detection. In practical engineering, rub-impact failures can be reduced by adjusting rotor-stator clearance, ensuring qualified dynamic balance, correcting deformation of foundation and casing, selecting matched shafts and bearings, lifting oil supply pressure and oil quality, preventing oil whip and dry friction, and strengthening real-time operation monitoring.

RUB-IMPACT VIBRATION OF CENTRIFUGAL COMPRESSOR

Fault Diagnosis of Rub-Impact Vibration

1. Diagnostic Methods for Rub-Impact Vibration

Rub-impact vibration of centrifugal air compressors is nonlinear with wide frequency bands and abundant spectral components. During signal collection, useful vibration signals are often mixed with wideband random noise and speed-related background signals. Conventional diagnostic methods struggle to filter out interference and extract effective rub-impact signals.

Traditional diagnosis relies mainly on spectrum diagrams and rotor orbit plots: technicians compare measured vibration frequency with characteristic frequency and check deformation of rotor orbits. However, this method delivers unsatisfactory accuracy. Overlapping of first-order and half-order frequency lines leads to ambiguous judgment, and typical nonlinear features of rub-impact easily cause misdiagnosis. Combined time-domain averaging and wavelet threshold denoising can process vibration signals effectively but suffer from slow computation speed. Wavelet transform realizes earlier fault identification yet lacks precision. Correlation dimension performs well in extracting rub-impact feature signals but still has limitations. Notably, rub-impact signals present weak amplitude modulation features, masked by heavy background noise and disturbances. Extracting amplitude-modulated fault information from measured vibration data becomes the core of rub-impact diagnosis. At present, Hilbert-Huang Transform (HHT) achieves remarkable, precise diagnostic performance for rub-impact faults. As a signal processing technique evolved from Hilbert Transform, HHT combines Empirical Mode Decomposition (EMD). For any non-stationary signal x(t), EMD decomposes it into a series of Intrinsic Mode Functions (IMF) (each with a single instantaneous frequency at every point) plus one residual component. Hilbert Transform is applied to each IMF sequence to generate analytical signals and corresponding instantaneous frequencies. Summing all IMF components and unfolding instantaneous frequencies yields the marginal spectrum, namely the Hilbert spectrum of the original non-stationary signal. The Hilbert spectrum obtained via HHT characterizes non-stationary signals in a high-resolution joint time-frequency domain. IMF decomposed by EMD carries definite physical meaning, accurately reflecting inherent system properties, retaining distinct fault features and eliminating false interference signals. HHT rapidly captures time-varying bearing frequencies, time-frequency components and marginal spectra of rub-impact vibration with concise curves that highlight fault features. It efficiently separates rub-impact fault signals from background noise and disturbances to acquire accurate fault information.

2. Locating Rub-Impact Fault Positions

Rub-impact positions can be judged by fluctuation and variation amplitude of vibration vectors at measuring points. Monitoring points are arranged to track not only vibration magnitude but also vibration variation, with priority given to phase besides amplitude. Vector comparison proves highly effective in practice.    (1) Vibration vector fluctuation and variation are most obvious near rub-impact points; variation amplitude declines as distance from the contact point increases.    (2) Under rated operating speed, if second-order components dominate vibration variation at both rotor ends, rub-impact mainly occurs on two ends; if first-order components dominate, friction mostly appears at the rotor middle or overhanging end. Presence of both first and second-order components indicates rub-impact at one rotor end.    (3) Large vibration variation at operating speed paired with minor variation at critical speed means rub-impact on both rotor ends; significant variation at both speeds points to rub-impact at one rotor end.

Retrofit & Improvement Solutions

Based on above analysis, the following measures can be adopted to eliminate rub-impact vibration:

1) Optimize rotor-stator clearance. Calculate critical rub-impact clearance according to compressor parameters. Ensure actual clearance exceeds the critical value to raise critical rub-impact frequency above operating frequency and avoid contact faults.

2) Avoid overloading. Excessive load prevents sufficient lifting of journal bearings, easily triggering friction between journal and bearing alloy to cause rub-impact. Moderate preload on bearings under normal conditions reduces rub-impact rotating speed and suppresses vibration.

3) Prevent operation near critical speed. Rub-impact vibration reaches its maximum intensity and damage level close to critical speed, so operating speed must stay far from critical ranges.

4) Control excessive shaft deflection. Excessive runout aggravates friction between shaft & seals and journal & bearings. Select matched shafts and bearings and reinforce unit foundations to reduce shaft wobble.

5) Eliminate rotor misalignment. Misalignment originates from mismatched coupling-shaft fit, improper bearing selection, assembly/maintenance alignment error, part machining tolerance and component wear during operation, all leading to rub-impact. Adjust rotor alignment and replace worn parts to mitigate vibration.

6) Strengthen operational monitoring and process control. Ramp up speed gradually during startup; narrow temperature differences to eliminate offset; prevent uneven thermal expansion; track vibration trends for early fault detection and rub-impact reduction.

7) Select qualified lubricating oil. Proper viscosity lowers running friction; adjust oil supply pressure and filter out impurities to cut rub-impact risks.

8) Complete standardized running-in. Strict running-in procedures are mandatory, especially for new units. Barring and warming expand rotor-stator clearance to prevent contact faults.