Analysis of the Causes of Sealing Failures in Industrial Pumps
2026-06-11 19:27

INDUSTRIAL PUMP MANUFACTURER


Seal failures of industrial pumps generally stem from two categories of structures:

1. Failure Manifestations & Causes of Packing Seal

Based on packing sealing principle, fluid leakage may occur through three paths inside the seal chamber: penetration through packing material, gaps between packing and stuffing box, and gaps between packing and shaft surface. Main failure phenomena and root causes are listed below:    ① Scuffed outer packing surface and leakage outside the gland: Caused by undersized outer diameter of packing rings.    ② Packing squeezed into gaps between shaft & retainer ring or shaft & gland: Usually resulting from excessively large design clearance or rotor eccentricity.    ③ Medium leaking along the packing gland: Triggered by incorrect packing installation or damaged retainer ring.    ④ Excessive leakage that cannot be adjusted: Reasons include swollen or damaged packing, improperly short-cut packing, wrong assembly, washed-out lubricant or uneven compression.

2. Failure Manifestations & Causes of Mechanical Seal

① Vibration and overheating of mechanical seal. During rotation, rough contact faces of rotating & stationary rings, tiny clearance between seal rings and chamber will produce impact vibration due to shaft runout. Vibration and heat can also arise from poor corrosion & temperature resistance of sealing faces, insufficient cooling, or granular impurities trapped between faces during installation.

② Medium leakage during static pressure test. Careless installation easily scratches, deforms or cracks sealing faces; uncleaned granular contaminants, loose set screws, insufficient gland compression or low machining precision will prevent full face fitting and cause leakage. If leakage appears at the shaft sleeve, the sleeve O-ring is not compressed enough, poorly installed or broken.

③ Periodic or intermittent leakage. Periodic vibration of the seal rotor assembly and excessive axial float will trigger intermittent leakage.

④ Persistent continuous leakage. Multiple potential causes exist: defects on primary sealing faces, faulty auxiliary O-rings, defective springs, rotor vibration, poor quality or loose transmission, fastening and thrust components.

⑤ Excessive mechanical seal vibration leading to complete seal failure. Excessive vibration is not always generated by the seal itself; other pump components can also be vibration sources.